Sun, 08/29/2021 - 19:27
I use VPhot for all my analysis.
Recently I began observing V0616 MON, which is below my observation limit (probably 2.5 mag below!). But There are several other variables in the FOV to report.
How can I use VPhot to analyze the other variables in the field and make a report while at the same time reporting that V0616 is fainter than whatever VPhot says my minimum is?? I think I can do it manually by modifying reports before I submit, but is there a more automated way of doing so??
Peter
BPEC
Peter:
On single image photometry page, see the <* column at the end of each target row.
Ken
I see that, but when I…
Ken,
I see that, but when I set up the sequence earlier VPhot failed to see the variable, so it is not on the target list. I guess a better way to ask my question is "if VPhot fails to see a target, how do I get it on the target list in order to report that it was below my magnitude shreshhold"?
Peter
Peter:
Don't you have another image that clearly shows the target when brighter? Use it to create your sequence.
Then set minimum SNR to 1 and you should pick it up in more images?
Ken
PS: Otherwise you need to edit the report manually.